• HIFI Audio Optical Transceiver

        ● RV6X4-2A         2-ch unidirectional HIFI
        ● RV6X4-4A         4-ch unidirectional HIFI
        ● RV6X4-4A-1U    4-ch unidirectional HIFI-1U
        ● RV6X4-8A         8-ch unidirectional HIFI
        ● RV6X4-2A-2BA   2-ch bidirectional HIFI
        ● RV6X4-4A-4BA   4-ch bidirectional HIFI

        ● Compact design with 1U height
        ● XLR interface for Audio
        ● SNR is better than 92dB
        ● 192K sampling frequency
        ● 24 bit quantized accuracy
        ● Provides AC110~220V dual power redundancy

      • SDI Converter

        ● 75ΩBNC connector for SDI input and looping out
        ● VGA output interface
        ● Two unbalanced RCA audio output with 600Ω impendence...

        ● Features 1 VGA input, 2 audio inputs and 1 SDI output
        ● Supports asymmetrical conversion for any format
        ● The input and output video format can be shown on the screen...

        75Ω BNC connector for SDI input and looping out

        ● HDMI output interface

        ● Two unbalanced RCA audio output with 600Ω impendence...

      • SDI Distribution Amplifier

      • 4U Rack Mounting Chassis

        ● 19 inch and 4U height
        ● 16 traffic card slots and 1 management card slot
        ● 3 fans embedded
        ● Dual power supplies for power redundant protection
        ● Provides one RS232 management interface(CONSOLE) used for CLI management...

      • HD-SDI Surge Protector

        and Pattern Generator

        ● Multi-level protection, low residual voltage
        ● Short response time   
        ● Large thermal capability and low limiting voltage
        ● Stable performance and long service life...

        ● Comply with SMPTE-424M 3G-SDI, SMPTE-292M HD-SDI and SMPTE-259M SD-SDI standard
        ● Support 1080P@59.94/29.97, 1080I@59.94, 720P@59.94, 525I@59.95 format of NTSC...

      • Fiber Optic Intrusion Detection System

      • Fiber Optic Intrusion Detection System Solution

      • Fiber Optic Intrusion Detection System Classic Case Series

      • Fiber Optic Intrusion Detection System Video Introduction

      • CHIP

      • Multi-Service Access Platform

        3U height, 19 Inch width standard, 9 card slots.

        Up to 2 GE optical ports and 2 GE electrical ports

        Aggregate the 1000M Ethernet traffic from up to 3 downlink cards...

        ● 7U height, 19 Inch width standard, 16 card slots.

        ● Up to 4 GE optical ports and 4 GE electrical ports.

        ● Each card can aggregate the 1000M Ethernet traffic from up to 8 downlink cards...

      • Converter

      • Compact SDH

      • Compact PDH

      • Channelized Industrial Ethernet switch

        Optical interface
        ● Two optical interfaces; SFP optical module (LC interface); Hot plugging...
        Ethernet interface
        ● RP105SA:One fiber and two copper Gigabit Ethernet interfaces
        ● RP106: Four fast Ethernet interfaces...

24577343-1
12160059
RS7000

Centralized MSAP (RS7000)

RS7000 is the centralized Multi-Service Access Platform (MSAP) compatible with ITU-T standard. It is designed as a cost-effective and flexible multi-service platform, with STM-1 / STM-4/STM-16 level uplink ports and abundant optional downlink cards to provide typical E1 traffic, PCM, optical tributary, EoSDH and EoPDH traffic access and aggregate...

● Download the password, please consult customer service

  • 999999999999999

     

     

    Overview

    RS7000 is the centralized Multi-Service Access Platform (MSAP) compatible with ITU-T standard. It is designed as a cost-effective and flexible multi-service platform, with STM-1 / STM-4/STM-16 level uplink ports and abundant optional downlink cards to provide typical E1 traffic, PCM, optical tributary, EoSDH and EoPDH traffic access and aggregate.

    As an important feature, in RS7000, the dual SDH uplink modules and dual Ethernet uplink modules can work simultaneously. Between each SDH uplink module and each sub-slot, there are STM-1 LVDS connections, and similarly, between each Ethernet uplink module and each sub-slot, there are LVDS Gigabit Ethernet connections. With this backplane design, TDM traffic in SDH/MSTP network and packet traffic in IP network can be distributed and aggregated in RS7000.

    A powerful timeslot cross-connection and IP data switching facility is supplied in RS7000. With the ability of connecting various network topologies, reliable self-healing mechanism, and unified intelligent management system, it is suitable for enterprise access, private network interconnection, mobile base stations connection and video monitoring applications.

    Feature

    Structure

    • 7U height, 19 Inch width standard, 16 card slots.
    • LVDS clock-free backplane, independent SDH bus and GE bus architecture.
    • Dual SDH uplink, dual Ethernet uplink and dual management units architecture ensure the system reliability.

    SDH uplink card

    • Up to 4× STM-1/STM-4/STM-16 interfaces .
    • LC type SFP module, hot-pluggable.
    • 98VC4×98VC4, or 96TU-3×96TU-3, 2016VC12×2016VC12 non-blocking cross-connection.
    • 1+1 line card protection to realize clock module hot-backup.
    • 1+1 linear unidirectional/ bidirectional Multiplex Section protection (MSP) and SNCP protection.
    • Point-to-point, chain, ring and tangent ring network topology.

    Ethernet uplink card

    • Up to 4 GE optical ports and 4 GE electrical ports.
    • Each card can aggregate the 1000M Ethernet traffic from up to 8 downlink cards, up to the 128 VCGs can be aggregated to the GE/GX port.

     Diversified downlink cards

    • Diversified downlink cards include optical downlink, E1, PCM and Ethernet downlink cards.
    • Communication with the remote Ethernet media converter, SDH,PCM and MSTP terminals.
    • Supports 1+1 path protection.
    • Supports the embedded E1 BERT testing function.
    • Compliant o Virtual concatenation (VCAT) and Link Capacity Adjustment Scheme (LCAS) recommendation G.7042

     Timing

    • Traces any timing source of STM-1/4/16 uplinks or STM-1 optical tributaries, or external timing source.
    • Supports External timing output.
    • The timing source can be switched manually or automatically.
    • Supports free-running, tracing and hold-over modes.

    System Management

    • Supports RayView network management platform based on C/S architecture.
    • Supports DCC and EXM (Extended E1 interface for management) channel for communication between gateway and elements.
    • Supports DCN channel for the communication between gateway and server.
    • Supports SNMP_V1 and SNMP_V2 protocol.
    • Supports local and remote firmware online update without disturbing existing traffic.
    • Provides top-mounted aural-visual alarm output.

     

     Card List

     

    Type

    Name

    Model

    Description

    Slots

    SDH uplink

    STM-16 uplink

    CU2501

    2×STM-16, DXC and SET.

    5, 8

    STM-4 uplink

    CU622

    2×STM-4, DXC and SET.

    STM-1 uplink

    CU155

    2×STM-1, DXC and SET.

    Ethernet uplink

    Ethernet uplink with layer 2 switch

    CUGE4A

    2×GX+2×GE, supports port-based VLAN and 802.1QVLAN, and trunk function.

    Aggregates the Giga Ethernet traffic from 8 slots at most.

    6, 7

    Downlink

    E1 mapping

    E1-16

    16 E1, 75Ω and 120Ω selectable.

    1-4, 6-7, 9-11

    E1-32

    32 E1, 75Ω and 120Ω selectable.

    1-4, 6-7, 9-1112

    PCM

    DXCCH30

    Full cross-connection among thirty 64Kb/s timeslot of 64E1, with the capacity of 1920*1920 64Kb/s. 8 PCM sub-module slots, up to 30 FXS/FXO/magneto voice channels or 16 2/4 wire E&M audio or 16 RS232/RS485/64K data interfaces totally.

    1-46-79-1112

    TUCH30

    8 PCM modules, up to 30 FXS/FXO/magneto voice channels or 16 2/4 wire E&M audio or 16 RS232/RS485/64K data interfaces totally.

    1-46-79-1112

    SDH optical tributary

    TU622-2

    2×STM-4, DXC,

    1-46-79-11

    TU155-8

    8×STM-1, DXC, supports P2P, P2MP, chain and ring topology.

    1-4, 6-7, 9-11

    TU155-4

    4×STM-1, DXC, supports P2P, P2MP, chain and ring topology.

    1-46-79-11

    PDH optical tributary

    TUP155-4

    4×PDH optical interface, DXC, used to connect remote PDH equipment, supports point-to-point and star-type network.

    1-46-79-11

    TUP155-8

    8×PDH optical interface, DXC, used to connect remote PDH equipment, supports point-to-point and star-type network.

    1-46-79-11

    TUP1250

    2×GE+2×OPT(1.25Gb/s), achieve 16 E1 and 2 gigabit Ethernet data transmission over optical line of 1.25Gb/s.

    Multiple 1GE&16E1 mixed traffic optical rings to enhance the traffic protection ability of the entire system.

    1-46-79-11

     

     

     

     

     

     

     

    EoSDH

    EOS-8FX8

    8×FX, 8 physical isolated VCG, with EoSDH, GFP/LCAS/VCAT, flow control, TS1000 protocol.

    1-4, 6-7, 9-11

    EOS-4FX4

    4×FX4 physical isolated VCG, with EoSDH, GFP/LCAS/VCAT, flow control, TS1000 protocol.

    1-4, 6-7, 9-11

    EOS-8FE8

    8×FE, 8 physical isolated VCG with EoSDH, GFP/LCAS/VCAT, and flow control.

    1-4, 6-7, 9-11

    EOS-8FE8A

    8×FE, 8VCG, EoSDH,GFP/LCAS/VCAT.

    With Ethernet switch, 8 Ethernet can also be aggregated to Giga Ethernet without EoSDH.

    Port-based VLAN and 802.1Q VLAN, QinQ.

    1-4, 6-7, 9-11

    EOS-4FE4A

    4×FE, 4VCG, EoSDH,GFP/LCAS/VCAT.

    With Ethernet switch, 4 Ethernet can also be aggregated to Giga Ethernet without EoSDH.

    Port-based VLAN and 802.1Q VLAN, QinQ.

    1-4, 6-7, 9-11

    EOS-16GE2A

    1 ×COMBO + 1 × GE + 1 × FE, 16VCG, EoSDH, GFP/LCAS/VCAT.

    With Ethernet switch, the Ethernet can also be aggregated to Giga Ethernet without EoSDH.

    Port-based VLAN and 802.1Q VLAN, QinQ.

    1-4, 6-7, 9-11

    EOS-2GE2A

    2×GE, EoS, 2VCG, up to 63 VC12 for each VCG.

    Port-based VLAN and 802.1Q VLAN, QinQ.

    Supports GFP/LCAS/VCAT.

    1-46-79-11

    GS4A

    Gigabit Ethernet to STM-4 converter, 4×GE, 1 VCG, up to 1~8 VC4,

    Port-based VLAN and 802.1Q VLAN, QinQ.

    Supports LCAS/VCAT.

    1-46-79-11

    Ethernet switch

    ETH-FX8A

    8×FX, port-based VLAN , 802.1Q VLAN, QinQ, TS1000 protocol. Achieve Ethernet aggregation from 8 remote Ethernet Media Converters.

    1-46-79-11

    ETH-FX4A

    4×FX, port-based VLAN , 802.1Q VLAN, QinQ, TS1000 protocol. Achieve Ethernet aggregation from 4 remote Ethernet Media Converters.

    1-46-79-11

     EoPDH

    EOP-16GE2A

    1×COMBO +1×GE+1×FE. 16VCG, EoPDH, LCAS/VCAT.

    With Ethernet switch, the Ethernet can also be aggregated to Giga Ethernet without EoSDH.

    Port-based VLAN and 802.1Q VLAN, QinQ. Supports GFP for multiple E1, and GFP/HDLC for single E1.

    1-4, 6-7, 9-11

    Management

    Management unit

    NMU7000

    Real time SNMP based management unit, supports hot-backup and cascading connection applications.

    12, 13

    Power

    DC power module

    RPW300DCM

    Redundant-backup Power modules, with the power consumption of 300W, supports management function, such as power input/output alarm indication.

    14, 15

    AC power module

    RPW300ACM

    14, 15

    DC power module

    RPW200DCM

    Redundant-backup Power modules, with the power consumption of 200W, supports management function, such as power input/output alarm indication.

    14,15

    AC power module

    RPW200ACM

    14,15

    Fan

    Fan tray

    FAN7000

    Fan tray

    16

    Fan tray with management

    FAN7000M

    Fan enable/disable and temperature threshold configurable, supports temperature display real time and fan alarm monitor.

    16

     

     

     Application

     

    rs3000

     

    Figure 1 Typical application

     

     

    Figure 2 PCM application

     

     

    0

Other  Products

PRODUCTS